ARQE 03 / PERFORMANCE
THE FORM IS UNEXPECTED.
THE PERFORMANCE ISN’T.
All performance figures are based on ARQE’s reported tests under defined conditions: 15°C water for cold starts; 180 ml of milk heated from 10°C to 60°C; and Scace brew-temperature testing on three preheated 230 V machines at a 93°C target, 25°C ambient temperature and 30-second shot intervals.
Results are indicative and may vary depending on operating conditions, equipment and preparation.
01 / WORKFLOW
The first minutes, measured.
What was measured
An espresso at three minutes and a cappuccino at three minutes thirty-five seconds from cold. The performance record reports these results; it does not supply a complete replicate count.
What the steam figure means
180 ml of milk was heated from 10°C to 60°C in 33 seconds. Milk type, pitcher, operator, voltage and initial machine state are not fully recorded; this is not a validated microfoam-quality result.
What happens between modes
Brewing, steaming and hot-water dispensing are separate operating modes. Turn off the active function and wait for flow to stop before selecting another. After steaming, return to brewing when the ready indicator permits; no zero-wait transition is established.
02 / HYBRID HEATING
One brew boiler. A dedicated steam stage.
Thermal RePass™ / inside the brew assembly
Brew water crosses an additional heated passage before the coffee. It is designed to counter some cooling associated with replacement water entering the boiler during extraction. PID regulation manages heating; the second passage does not prove a perfectly flat puck temperature.
Steam Head Start™ / what changes versus other layouts
A conventional thermoblock can heat feed water entering nearer tank temperature; a traditional dual-boiler instead stores a separate volume at steam temperature. ARQE feeds its dedicated steam heating block with water already heated by the brew boiler, so that stage adds the remaining energy for steam. It does not mean simultaneous brewing and steaming, instant steam, or unlimited output.
Dynamic Power Sharing / electrical reality
The control system allocates the available 1450 W machine budget between brewing and steam demands. Although the two heating elements are each rated 1400 W, those ratings are not additive. It is a managed two-stage system, not two independently full-powered heaters running together.
A CLOSER LOOK / HEATFORWARD™
How ARQE manages heat.
Three simple ideas: keep brew water hot, give steam a head start, and send power where it is needed.

03 / STEAM
Steam from preheated water—not a steam reservoir.

04 / TEMPERATURE & CONTROL
Pressure and pre-infusion, without presets.
05 / COMPARISON
Architecture first. Benchmarks in context.
Architecture comparisons describe system design; they are not controlled performance comparisons. “Reported” refers to ARQE test results; “specified” describes documented machine configurations or requirements. Source: ARQE 03 Performance & Technical Guide, October 2026.